Menu Settings

Dive in to the menu settings for a custom experience.

ree
  • Press left on the joystick to access the menu for settings.

  • Use up/down or left/right to scroll between options or fields.

  • Center press the joystick in to select an option or a field.

  • Use up/down or left/right to change field values and press center when complete.


User preferences


ree
  • Screen backlight: Default setting is auto and will turn on in dim conditions; off will prevent it from turning on and extend battery life; on to have it on at all times.

  • Contrast: Increase to darken the black areas, decrease to lighten.

  • Show 25% drop alert: When used with Pressure Senders the display can alert the user when the current pressure has dropped 25% below the last recorded pressure.


Flow device config

If you are using flow enabled Sender's, you must enter information about your flow device for the display to calculate GPM from the pressure. This information should be obtained from the data sheet for your specific device.

ree
  • Brand: Select the manufacture from the drop down list. Some manufacture's use a correction factor for large outlet diameters such as 4". The display will use this correction if required. If the manufacture is not listed, use the Generic selection.

  • Outlet Diameter: Select the flow outlet diameter from the drop down list.

  • Coefficient: Enter the coefficient for your specific device from the manufacture data sheet.


Menu lock

If you do not want users to be able to access the menu and adjust settings you can apply a menu lock. This will require a passcode to be entered before the menu will be displayed.

ree

Check the box for Use menu lock and enter a 3 digit passcode. You can use A - Z, a - z and 0 - 9 for your passcode. If you forget your passcode please contact support for assistance.


Device group

Device Group ID's are used to limit communication between different sets of Sender/Display units. Devices will only communicate with other devices that have the same Group ID number. Senders and Displays have a default Group ID set to 1. If you have multiple sets and do not want them to talk to each other, set a different ID on each set. See the Device Group section for detailed information on how to set them.


Radio range

For special cases where you have a very long distance or a lot of obstructions between the Sender and Display you can increase the radio range setting. Longer distances require more time to transmit so the longer the range the slower a Sender will send data. See the Radio Range section for detailed information on how to set them.


Zero Pressure

If you need to re-zero the pressure on your Sender(s) you can use the Zero Pressure function. To use this you must ensure the following:

  • Sender is powered on

  • Sender is near the display and you can see it's status light

  • Sender is not connected to any pressure source

ree

Check the Set Zero box and scroll down to OK. When you select OK the display will send a command to the Sender(s) to set zero pressure. The Sender's status light will flash yellow 3 times indicating it received the command and re-zero. It will return to normal operation after it is complete.


Exit

Scroll to the bottom of the menu and select Exit to leave the menu system.

ree

Center press the joystick to Save and Exit the menu system. If you do not want any changes made to be saved, press the reset button to restart the display.